Autotransformer
The auto-transformers are frequently used like an economic alternative to the distribution transformers. It allows the adjustment of the output voltage for specific charges like the heating or drive forces for industrial machines. The primary and the secondary of an auto-transformer are on same winding, instead of being on two separate windings like an isolation transformer. However this alternative cannot be employed on certain feeding systems: when the neutral on the secondary must be used or grounded and when the neutral of the primary winding is not available.
Features : - Taps: 1-5% FCAN, 1-5% FCBN.
- Three coils design, neutral available.
- Low initial cost.
- Small compact size.
- May be used as step-up or step-down.
- Low regulation : less than 3%.
- Available in copper.
- Option: Primary 600, 480, 460, 440 Volts Secondary 600, 240, 230, 220, 208 Volts
Different size connectors available on request.
Connectors Type Technical Drawing

Connectors Type Primary : 600V, Secondary 480V
| KVA |
Code |
High Voltage |
Low Voltage |
| 30 |
BC2030S480 |
1 x 2-14 |
1 x 2-14 |
| 45 |
BC2045S480 |
1 x 2-14 |
1 x 2-14 |
| 75 |
BC2075S480 |
1 x 2 / 0-6 |
1 x 2 / 0-6 |
| 112.5 |
BC2112S480 |
1 x 2 / 0-6 |
1 x 2 / 0-6 |
| 150 |
BC2150S480 |
1 x 250 MCM |
1 x 250 MCM |
| 225 |
BC2225S480 |
1 x 350 MCM |
1 x 500 MCM |
| 300 |
BC2300S480 |
1 x 500 MCM |
1 x 350 MCM |
| 400 |
BC2400S480 |
1 x 350 MCM |
1 x 350 MCM |
| 500 |
BC2500S480 |
1 x 350 MCM |
1 x 500 MCM |
| 600 |
BC2600S480 |
1 x 500 MCM |
1 x 500 MCM |
Primary : 600V, Secondary : 380V
| KVA |
Code |
High Voltage |
Low Voltage |
| 20 |
BC2020S380 |
1 x 2-14 |
1 x 2-14 |
| 30 |
BC2030S380 |
1 x 2-14 |
1 x 2-14 |
| 45 |
BC2045S380 |
1 x 2-14 |
1 x 2 / 0-6 |
| 75 |
BC2075S380 |
1 x 2 / 0-6 |
1 x 2 / 0-6 |
| 112.5 |
BC2112S380 |
1 x 2 / 0-6 |
1 x 250 MCM |
| 150 |
BC2150S380 |
1 x 250 MCM |
1 x 350 MCM |
| 225 |
BC2225S380 |
1 x 350 MCM |
1 x 600 MCM |
| 300 |
BC2300S380 |
1 x 500 MCM |
2 x 350 MCM |
| 400 |
BC2400S380 |
2 x 350 MCM |
2 x 500 MCM |
| 500 |
BC2500S380 |
2 x 350 MCM |
3 x 500 MCM |
| 600 |
BC2600S380 |
2 x 500 MCM |
3 x 500 MCM |
Primary : 600V, Secondary : 240V
| KVA |
Code |
High Voltage |
Low Voltage |
| 10 |
BC2010S240 |
1 x 2-14 |
1 x 2-14 |
| 15 |
BC2015S240 |
1 x 2-14 |
1 x 2-14 |
| 20 |
BC2020S240 |
1 x 2-14 |
1 x 2-14 |
| 30 |
BC2030S240 |
1 x 2-14 |
1 x 2 / 0-6 |
| 45 |
BC2045S240 |
1 x 2-14 |
1 x 2 / 0-6 |
| 75 |
BC2075S240 |
1 x 2 / 0-6 |
1 x 250 MCM |
| 112.5 |
BC2112S240 |
1 x 2 / 0-6 |
1 x 500 MCM |
| 150 |
BC2150S240 |
1 x 250 MCM |
2 x 350 MCM |
| 225 |
BC2225S240 |
1 x 350 MCM |
2 x 500 MCM |
| 300 |
BC2300S240 |
1 x 500 MCM |
3 x 500 MCM |
| 400 |
BC2400S240 |
2 x 350 MCM |
3 x 600 MCM |
| 500 |
BC2500S240 |
2 x 350 MCM |
4 x 500 MCM |
| 600 |
BC2600S240 |
2 x 500 MCM |
5 x 600 MCM |
Technical Drawing
Auto Transformer : 3 Phases
|
|